Redundancy Switches
Redundancy switches provide a standby signal path that is shared among one or several identical paths. Redundancy switches can be used to automatically route around failed amplifiers, optical components, receivers, transmission paths, etc.
Relay Switches
Part Number | 1 for N | Frequency Range | Insertion Loss dB (2) | Isolation dB (3) | VSWR (50 Ω) | Control Interface Normal (4) |
---|---|---|---|---|---|---|
RS-1000-4-IF | 1 for 4 | 10 – 200 MHz | 2.0 | 80 | 1.3:1 | RS-232/422 |
RS-1000-5-IF | 1 for 5 | 10 – 200 MHz | 2.0 | 80 | 1.3:1 | RS-232/422 |
RS-1000-6-IF | 1 for 6 | 10 – 200 MHz | 2.0 | 80 | 1.3:1 | RS-232/422 |
RS-1000-8-IF | 1 for 8 | 10 – 200 MHz | 2.0 | 80 | 1.3:1 | RS-232/422 |
RS-1000-4-LB | 1 for 4 | 950 – 2150 MHz | 5.0 | 70 | 1.5:1 | RS-232/422 |
RS-1000-5-LB | 1 for 5 | 950 – 2150 MHz | 5.0 | 70 | 1.5:1 | RS-232/422 |
RS-1000-6-LB | 1 for 6 | 950 – 2150 MHz | 5.0 | 70 | 1.5:1 | RS-232/422 |
RS-1000-8-LB | 1 for 8 | 950 – 2150 MHz | 5.0 | 70 | 1.5:1 | RS-232/422 |
Notes:
- The RS-100X consists of two modules, one transmit, one receive.
- Insertion Loss is specified end-to-end.
- Isolation is specified end-to-end.
- The control algorithm is set via dipswitch. Optional Ethernet control is available.
- 75 ohm impedance available.
Solid State Switches
Part Number | 1 for N | Frequency Range | Insertion Loss dB (2) | Isolation dB (3) | VSWR (50 Ω) | Control Interface Normal (4) |
---|---|---|---|---|---|---|
RS-1001-4-LB | 1 for 4 | 950 – 2150 MHz | 5.0 | 80 | 1.3:1 | RS-232/422 |
RS-1001-5-LB | 1 for 5 | 950 – 2150 MHz | 5.0 | 80 | 1.3:1 | RS-232/422 |
RS-1001-6-LB | 1 for 6 | 950 – 2150 MHz | 5.0 | 80 | 1.3:1 | RS-232/422 |
RS-1001-8-LB | 1 for 8 | 950 – 2150 MHz | 5.0 | 80 | 1.3:1 | RS-232/422 |
RS-1001-4-MW | 1 for 4 | 0.5 – 18 GHz | 2.0 | 80 | 1.5:1 | RS-232/422 |
RS-1001-5-MW | 1 for 5 | 0.5 – 18 GHz | 2.0 | 80 | 1.5:1 | RS-232/422 |
RS-1001-6-MW | 1 for 6 | 0.5 – 18 GHz | 2.0 | 80 | 1.5:1 | RS-232/422 |
RS-1001-8-MW | 1 for 8 | 0.5 – 18 GHz | 2.0 | 80 | 1.5:1 | RS-232/422 |
Notes:
- The RS-100X consists of two modules, one transmit, one receive.
- Insertion Loss is specified end-to-end.
- Isolation is specified end-to-end.
- The control algorithm is set via dipswitch. Optional Ethernet control is available.
- 75 ohm impedance available.